Meters & Loggers: VARLOG™ 

wpeB.jpg (14177 bytes) wpeC.jpg (20306 bytes)

Every Power distribution system requires reliable metering of various electrical parameters. From the electricity user’s point of view, this is important for saving of electrical energy, where-ever possible. For the utility provider however, accurate & reliable metering is vital if he is to use the distribution optimally. Not only should every distribution transformer be loaded maximum, but also operate at near unity power factor. The load imbalance on the three phases should be within reasonable limits. Thus, information like amount of loading imbalance, power factors at different times of the day, peak loading hour etc. can be of great help in planning distribution of power and also implementing automatic switched capacitor systems to maintain power factor near unity.

Once having implemented a switched capacitor scheme, the provider would also like to know how the scheme is performing, the rating and health of capacitors etc. This is where VARLOG™ comes in.
 
VARLOG™ is an electrical parameter measurement instrument and logger which measures / calculates and displays the following parameters :
 
1. Three phase voltages.
2. Three phase (load) currents.
3. Frequency.
4. Power Factor
5. System KVA, KW & KVAR
6. Three phase (capacitor) currents
7. Capacitor KVAR
8. Date & Time

In addition to this, VARLOG™, also logs all these parameters in it’s non-volatile memory, every four minutes. There is no need for any manual intervention here. Afterwards, any operator can download the recorded data on an IBM compatible, using the serial link provided. This data yields itself to further analysis like load current without capacitors, Power factor without capacitors etc. and the utility provider can actually calculate KVA saved and quantify it in terms of currency.

Other Features:

  • VARLOG™ not only monitors load currents but also capacitor currents thus allowing utility company to know whether capacitors are de-rated or failed.
  • VARLOG™ is meant for use in three phase four wire L.T. electrical system. It uses the three watt-meter method to calculate KVA, KW & KVAR.
  • VARLOG™ is based on a powerful 8-bit micro-controller operating at 16 MHz. The controller receives voltage & current signals which are fully isolated and performs high speed measurement and calculations, typically finishing one complete measurement cycle in less than a second.
  • The unit displays all parameters locally on a 16 x 1 STN LCD. The user-friendly membrane keypad on the front makes programming the unit (for C.T. ratios etc. ) very easy.
  • VARLOG™ has a FIFO buffer for logging data. If the buffer gets full, the oldest record shifts out and the new data shifts in. Thus, when the data is downloaded, the records of the last 100 hours or so will be sent down by the VARLOG™ to the PC.
  • VARLOG™ is thus a very versatile and accurate information interface for both the utility provider and end user.

SPECIAL FEATURE OF VARLOG™: PROGRAMMABLE FEATURE: The VARLOG™ has basically five programmable parameters : date, day of week, time, CT ratio for load currents and CT ratio for capacitor currents. These have to be programmed, in most cases, only once at the time of commissioning a new unit. To differentiate between programming operations and normal functioning of the unit, VARLOG™ has two modes of operation: PROG mode and RUN mode. Whenever the unit is powered ON it is in the RUN mode. It is in this mode that it displays all the parameters one by one on the front LCD. To set any of the above mentioned programmable values, the user has to go into RUN mode, set/change the values and return to RUN mode.

SPECIAL FEATURE OF THE SOFTWARE: CAPABILITY FOR IMPORTING TO MS-EXCEL: The file created after filter is basically an ascii file. One can directly view it using any ascii text editor and print it. However, in order to do further calculations or maybe generate graphs, it is best to use a spread-sheet package. Lotus does not import ascii files. However, MS-EXCEL is a spread-sheet package which easily imports ascii data. It is also very user friendly. To read file into EXCEL, just run EXCEL from Windows and giving read file option, select our filename as c:\procomm\jubilee.log. The file will get opened in EXCEL.

Technical Specifications
Electrical System
3 Phase, 4 Wire System
Voltage Connections
R.Y.B and Neutral
Current Connections
3 CT secondaries (5 Amps) from system. One from each phase.
CT Ratios
CT ratios for system current will be site Programmable
Operator Interface
Membrane Keypad (16 keys - 4X4 matrix) on the front of the unit, used for programming various parameters like date, time and CT ratios.
Local Alphanumeric display, 16 X 1 LCD
Displayed Parameter
Vr, Vy, Vb, Ir, Iy, Ib, PF, Frequency, KVA, KW, KVAR, Day, Date and time. Each Parameter is displayed for the duration of 6 secs.
Parameters Logged and Transferred to PC
Vry, Vyb, Vbr, Ir, Iy, Ib, PF, KVA, KW, un-compensated, KVAR, ILR, ILY, ILB.
Connectivity to PC
RS232C Link, 9 Pin D Connector on the PC end. Communication parameters: 4800 baud, 7 databits, odd parity 1 stopbit.
Max Number of Records Logged
1200 records. After that, when the new record comes in, oldest record is pushed out and new record is added
Frequency of Logging
One record logged every 4 minutes between 6 AM and Midnight. Between midnight and 6 AM, one record every 6 minutes. This is the default setting and is programmable.
Size
Panel Cutout: 138mm x 138mm
Bezel: 144mm x 144mm
Depth: 140 mm with terminal (max)
Weight: 4Kgs.
Additional Features (Optional)
Logger can be modified as per customer requirement like extending number of records to log data for 30 days, logging of Capacitor current etc., as additional features at additional cost.

 